Mouse

Vertical level regulator suitable for narrow spaces where regular floats do not have enough room to move. At user’s will the floating bodies can be moved along the shaft to regulate the minimum and maximum level. Shaft is available in different lengths.

Mouse requires periodic check-ups of its parts.

Patented

 
CLEAN WATER
 RAIN WATEr
INDUSTRIAL WATER
WATER CONTAINING CHEMICAL SUBSTANCES

Principle of Operation

Based on the magnet and the weight

The tank fills up. The water reaches the maximum level and the whole floating body raises

The max level turns the pump ON and the tank drains

The water reaches the minimum level and the weight of the floating body disengages the magnet

The min. level turns OFF the pump

Examples of Applications

SPST-NO / SPDT-NO

Single Function - Normally Open: Emptying / Double Function - Normally Open: Emptying

SPDT-NC

Double Function - Normally Closed: Filling

Shafts

Shaft is available in different lengths

Cables

Neoprene cables IMQ certified

Available Lenghts

0,52 - 3 - 5 - 10 - 15 - 20 m

Available Types

H07 RN-F 3G1 - Ø 8,8mm
H05 RN-F 3X1 - Ø 7,4mm
H07 RN8-F 3G1 - Ø 8,8mm
H07 RN-F 3G1 oil resistant - Ø 8,8mm

Power Supply

Best European Microswitches

Technical Features

clean contacts support
min 0,1A
min 12/24V

Types

10(8)A 250V for pumps till 1,5HP
10(10)A 250V for pumps till 2HP

Others Features

Temperature

max.+50°C (+122°F)

Depth

max.10m - 32,8ft

Protection Grade

IP 68

Accessories

Brackets and Supports

Polypropilene Bracket*

tube or wall fixing

Stainless Steel Bracket*

AISI 304

Flanged Support*

2"

Threaded Support*

2" GAS

*Available On Request