Snake UL

In combination with Probes or Taurus (sold separately) it allows the installation of the control body at a very long distances from the workstations.
 
CLEAN WATER
 RAIN WATEr
INDUSTRIAL WATER
WATER CONTAINING CHEMICAL SUBSTANCES

Principle of Operation

Based on the electrical conductivity of the water

Snake with Taurus*

Snake with Level Probes*

Factory Delay Times

Start

0"

Stop

0"

Setting Delay Times

By means of the supplied magnetic key, the customer is able to adjust the delay time of start and stop according to its own needs of use.

Setting Start Delay Time

  1. Disconnect the plug from the electrical system;
  2. Put the magnetic key close to the arrow stamped on the side of the electronic controller;
  3. Connect the plug to turn on the pump;
  4. Hold the magnetic key in position for how many seconds you wish to delay the starting time (maximum 120 seconds);
  5. Once you got the desired delay time, remove the magnetic key.

Setting Stop Delay Time

  1. Connect the plug to the electrical system;
  2. Wait for the pump shutdown;
  3. Put the magnetic key close to the arrow shown on the side of the electronic regulator and the pump starts;
  4. Hold the magnetic key in posion for the seconds necessary to delay the shutdown (maximum 120 seconds);
  5. Once reached the desired time, remove the magnetic key.

Available Types

Made in Italy Motherboards; Neoprene and Oil Resistant cables for better performances

Accessories

Brackets and Supports

Polypropilene Bracket*

tube or wall fixing

Stainless Steel Bracket*

AISI 304

*Available On Request