Spider
The rods attached to the body allow the level regulator to work in narrow spaces and in difficult environments with turbulent waters.
PATENTED PRODUCT
Applications:
CLEAN WATER
RAIN WATER
INDUSTRIAL WATER
WATER CONTAINING CHEMICAL SUBSTANCES
RAIN WATER
INDUSTRIAL WATER
WATER CONTAINING CHEMICAL SUBSTANCES
Download:
Principle of Operation
Based on the electrical conductivity of the water
Spider is connected to 3 batons: Common as ground - Min as minimuml level - Max as maximul level
The water reaches the weel and the level increases
Spider turns ON the pump when the maximum level baton detects the water
The water level decreases and Spider turns OFF the pump when the minimum level baton doesn’t detect the water anymore
Examples of Applications
SPST-NO
Single Function - Normally Open: Emptying
SPST-NC
Single Function - Normally Closed: Filling
Factory Delay Times
Start
0"
Stop
0"
Setting Delay Times
By means of the supplied magnetic key, the customer is able to adjust the delay time of start and stop according to its own needs of use.
Setting Start Delay Time
- Disconnect the plug from the electrical system;
- Put the magnetic key close to the arrow stamped on the side of the electronic controller;
- Connect the plug to turn on the pump;
- Hold the magnetic key in position for how many seconds you wish to delay the starting time (maximum 120 seconds);
- Once you got the desired delay time, remove the magnetic key.
Setting Stop Delay Time
- Connect the plug to the electrical system;
- Wait for the pump shutdown;
- Put the magnetic key close to the arrow shown on the side of the electronic regulator and the pump starts;
- Hold the magnetic key in posion for the seconds necessary to delay the shutdown (maximum 120 seconds);
- Once reached the desired time, remove the magnetic key.
Available Electrical connectons
Standard Applications
Solutions for pump manufacturers
Technical Datas
Casing: Polypropylene
Grommet: TPV
Batons: AISI 316-> 250/500/750mm
International Protection: IP68
MODEL | NEOPRENE CABLE | LENGHT (m) | POWER SUPPLY | TEMPERATURE | DEPTH | NOTE |
---|---|---|---|---|---|---|
SPIDER (230v) | H07 4G1 SPST-NO | 0,70 / 5 / 10 | 230Vac 50/60Hz 5A | max.+40°C (+104°F) | max.10m (32,8ft) | for pumps till 1,5HP |
SPIDER (12V) | H07 4G1 SPST-NO | 0,70 / 5 / 10 | 12/24Vac/dc | max.+40°C (+104°F) | max.10m (32,8ft) | for pumps till 1,5HP |
Accessories
Brackets and Supports
(* May not be included)
Polipropylene Bracket
tube or wall fixing
Stainless steel bracket *
aisi 304
Supports
tank fixing
Flanged*
2"
Threaded*
2" Gas
Schuko Piggyback Plug*
The schuko piggyback plug provided with the float switch allows to connect a pump without a switch directly to an electrical socket as to controll the start and stop function.